Guralp-systems Strong Motion Manual do Utilizador

Consulte online ou descarregue Manual do Utilizador para Software Guralp-systems Strong Motion. Guralp Systems Strong Motion User Manual Manual do Utilizador

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 17
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 0
Strong Motion
User Guide
User guide
Part No. MAN-SMO-0001
Designed and manufactured by
Güralp Systems Limited
3 Midas House, Calleva Park
Aldermaston RG7 8EA
England
Proprietary Notice: The information in this
manual is proprietary to Güralp Systems Limited
and may not be copied or distributed outside the
approved recipient's organisation without the
approval of Güralp Systems Limited. Güralp
Systems Limited shall not be liable for technical
or editorial errors or omissions made herein, nor
for incidental or consequential damages resulting
from the furnishing, performance, or usage of this
material.
Issue F 2008-07-18
Vista de página 0
1 2 3 4 5 6 ... 16 17

Resumo do Conteúdo

Página 1 - User Guide

Strong Motion User GuideUser guidePart No. MAN-SMO-0001Designed and manufactured byGüralp Systems Limited3 Midas House, Calleva ParkAldermaston RG7 8E

Página 2 - Table of Contents

Strong Motion User Guide3 Viewing ResultsCurrently, the Scream software does not allow display of strong motion or unified status packets. This featur

Página 3 - 1 Introduction

Güralp Systems Ltd.3.2 The Strong Motion PacketThe strong motion packet contains calculated strong motion data in floating point format.

Página 4

Strong Motion User Guide3.4 CMG-STA-DISP Display UnitAs part of a seismic hazard monitoring system, a real-time display unit (th

Página 5 - 2 Digitiser Configuration

Güralp Systems Ltd.4 Calculation DetailsThis section describes the concept of the strong motion calculations. The document SWA-RFC-STM

Página 6 - 2.3 Basic setup

Strong Motion User Guideis a set of four cascaded first-order IIR filters. Its roll off is comparitively more shallow and begi

Página 7 - 2.4 Enable strong motion mode

Güralp Systems Ltd.4.2 Types of Strong Motion ResultThe following strong motion results are calculated every second, in real-time. They

Página 8 - 2.5 Common scenarios

Strong Motion User GuideRMS (root mean square)The RMS is computed every second and is the root mean square of the digital counts f

Página 9

Güralp Systems Ltd.5 Revision history2008-07-18 F Add LLstreams enable command. Add section on firmware changes.2008-06-06 E Add uspmonitor command.20

Página 10 - 3 Viewing Results

Strong Motion User GuideTable of Contents1 Introduction...31.1 Firmware change

Página 11 - 3.3 Viewing Packets

Güralp Systems Ltd.1 IntroductionThe CMG-DM24mk3 digitiser is capable of performing several calculations useful for strong motion study. T

Página 12 - 3.4 CMG-STA-DISP Display Unit

Strong Motion User Guidethe “LLstreams enable” command. The data may be turned off at any time with “LLstreams disable”.This build also fixes

Página 13 - 4 Calculation Details

Güralp Systems Ltd.2 Digitiser ConfigurationBelow is a set of commands, including sample output, that should be used to set up the D

Página 14 - FIR filter

Strong Motion User Guideserial2Secondary Serial # { 0 } ? 6 characters : B808 B80800 ok_A808GSL recommend that the system identifier is set to the di

Página 15

Güralp Systems Ltd.should improve the quality of strong motion results.2.4 Enable strong motion modeThe CMG-DM24 has a flexible system of output taps

Página 16 - RMS (root mean square)

Strong Motion User GuideThe first hex code could be 77000000 to enable 200sps data on both sensors (or 07000000 for Sensor A only), 000000

Página 17 - 5 Revision history

Güralp Systems Ltd.6 sensor-type (for CMG-5T)adaptive (if desired)erasefilenormal compression0 1 bandpass3 highpass200 100 20 10 samples/seclowlatency

Comentários a estes Manuais